Applications
- Cooling electronic controls
- Cooling machining operations
- Cooling CCTV cameras
- Setting hot melts
- Cooling soldered parts
- Cooling gas samples
- Electronic component cooling
- Cooling heat seals
- Cooling environmental chambers
Advantages
- No moving parts
- No electricity or chemicals
- Small, lightweight
- Low cost
- Maintenance free
- Instant cold air
- Durable - stainless steel
- Adjustable temperature
- Interchangeable generators
Accessories |
|
Model | Description |
3905 | Cold Muffler for 2 through 8 SCFM (57 - 227 SLPM) Vortex Tube, Small Size |
3901 | Cold Muffler for 10 through 40 SCFM (283 - 1,133 SLPM) Vortex Tube, Medium Size |
3906 | Cold Muffler for 50 through 150 SCFM (1,416 - 4,248 SLPM) Vortex Tube, Large Size |
3903 | Hot Muffler for 2 through 40 SCFM (57 - 1,133 SLPM) Vortex Tube, Small & Medium Size |
3907 | Hot Muffler for 50 through 150 SCFM (1,416 - 4,248 SLPM) Vortex Tube, Large Size |
3909 | Generator Kit for 2 through 8 SCFM (57 - 227 SLPM) Vortex Tube, Small Size |
3902 | Generator Kit for 10 through 40 SCFM (283 - 1,133 SLPM) Vortex Tube, Medium Size |
3910 | Generator Kit for 50 through 150 SCFM (1,416 - 4,248 SLPM) Vortex Tube, Large Size |
Generator Kits ordered with a vortex tube include all generators for the specified tube. Permits setting the vortex tube for all capacities and styles. Generator Only —Specify capacity (SCFM) and style (“R†for max. refrigeration, “C†for max. cold temperature). Example: 15-R = 15 SCFM Generator for max. refrigeration 50-C = 50 SCFM Generator for max. cold temperature |
Vortex Tube Performance
The Vortex Tube Performance Charts below give approximate temperature drops (and rises) from inlet air temperature produced by a vortex tube set at each cold fraction. Assuming no fluctuation of inlet temperature or pressure, a vortex tube will reliably maintain temperature within ±1°F.
Pressure Supply |
Cold Fraction % |
||||||
PSIG | 20 | 30 | 40 | 50 | 60 | 70 | 80 |
20 | 62 | 60 | 56 | 51 | 44 | 36 | 28 |
15 | 25 | 36 | 50 | 64 | 83 | 107 | |
40 | 88 | 85 | 80 | 73 | 63 | 52 | 38 |
21 | 35 | 52 | 71 | 92 | 117 | 147 | |
60 | 104 | 100 | 93 | 84 | 73 | 60 | 46 |
24 | 40 | 59 | 80 | 104 | 132 | 166 | |
80 | 115 | 110 | 102 | 92 | 80 | 66 | 50 |
25 | 43 | 63 | 86 | 113 | 143 | 180 | |
100 | 123 | 118 | 110 | 100 | 86 | 71 | 54 |
26 | 45 | 67 | 90 | 119 | 151 | 191 | |
120 | 129 | 124 | 116 | 104 | 91 | 74 | 55 |
26 | 46 | 69 | 94 | 123 | 156 | 195 | |
Numbers in shaded area show temperature drop of cold air (°F). | |||||||
Numbers in unshaded area show temperature rise of hot air (°F). |
Pressure Supply |
Cold Fraction % (METRIC) |
||||||
BAR | 20 | 30 | 40 | 50 | 60 | 70 | 80 |
1.4 | 34.4 | 33.3 | 31.1 | 28.3 | 24.4 | 20 | 15.6 |
8.3 | 13.9 | 20 | 28.3 | 35.6 | 46.1 | 59.4 | |
2 | 40.9 | 39.6 | 37.1 | 33.8 | 29.2 | 24 | 18.1 |
9.8 | 16.4 | 24 | 33.3 | 42.6 | 54.6 | 69.5 | |
3 | 50.4 | 48.7 | 45.7 | 41.6 | 36 | 29.7 | 21.9 |
12 | 19.9 | 29.6 | 40.3 | 52.3 | 66.5 | 83.5 | |
4 | 56.9 | 54.7 | 50.9 | 46.1 | 40 | 32.9 | 25.1 |
13.2 | 21.9 | 32.4 | 43.9 | 57.1 | 72.5 | 91.2 | |
5 | 61.6 | 59 | 54.8 | 49.4 | 43 | 35.4 | 26.9 |
13.7 | 23.3 | 34.2 | 46.5 | 60.9 | 77.2 | 97.1 | |
6 | 65.4 | 62.7 | 58.2 | 52.7 | 45.6 | 37.6 | 28.6 |
14.1 | 24.3 | 35.8 | 48.6 | 63.9 | 81 | 102.1 | |
7 | 68.6 | 65.8 | 61.4 | 55.7 | 48 | 39.6 | 30 |
14.4 | 25.1 | 37.3 | 50.2 | 66.3 | 84.2 | 106.3 | |
8 | 71.1 | 68.2 | 63.8 | 57.3 | 50 | 40.8 | 30.4 |
14.4 | 25.4 | 38.1 | 51.8 | 67.9 | 86.1 | 107.9 | |
Numbers in shaded area show temperature drop of cold air (°C). | |||||||
Numbers in unshaded area show temperature rise of hot air (°C). |
Back Pressure: The performance of a vortex tube deteriorates with back pressure on the cold air exhaust. Low back pressure, up to 2 PSIG (.1 BAR), will not change performance. 5 PSIG (.3 BAR) will change performance by approximately 5°F (2.8°C).
Filtration: The use of clean air is essential, and filtration of 25 microns or less is recommended. EXAIR filters contain a five micron element and are properly sized for flow.
Inlet Air Temperature: A vortex tube provides a temperature drop from supply air temperature (see Performance Charts above). Elevated inlet temperatures will produce a corresponding rise in cold air temperatures.
Noise Muffling: EXAIR offers mufflers for both the hot and cold air discharge. Normally, muffling is not required if the cold air is ducted.
Regulation: For best performance, use line pressures of 80 to 110 PSIG (5.5 to 7.6 BAR). Maximum pressure rating is 250 PSIG (17.2 BAR), minimum 20 PSIG (1.4 BAR).
Vortex Tube Specifications
3200 Series Vortex Tube Specifications |
||||||
3200 series Vortex Tubes optimize temperature drop and airflow to produce maximum cooling power or Btu/hr. (Watts). Specify 3200 series Vortex Tubes for most general cooling applications. | ||||||
Model # | SCFM* | SLPM* | Btu/hr.** | Watts** | Size | dBA*** |
3202 | 2 | 57 | 135 | 40 | Small | 68 |
3204 | 4 | 113 | 275 | 80 | Small | 70 |
3208 | 8 | 227 | 550 | 162 | Small | 76 |
3210 | 10 | 283 | 650 | 191 | Medium | 80 |
3215 | 15 | 425 | 1,000 | 293 | Medium | 81 |
3225 | 25 | 708 | 1,700 | 498 | Medium | 82 |
3230 | 30 | 850 | 2,000 | 586 | Medium | 84 |
3240 | 40 | 1,133 | 2,800 | 821 | Medium | 88 |
3250 | 50 | 1,416 | 3,400 | 997 | Large | 94 |
3275 | 75 | 2,124 | 5,100 | 1,494 | Large | 96 |
3298 | 100 | 2,832 | 6,800 | 1,993 | Large | 96 |
3299 | 150 | 4,248 | 10,200 | 2,989 | Large | 97 |
* SCFM (SLPM) at 100 PSIG (6.9 BAR) Inlet Pressure ** Btu/hr. (Watts) Cooling Capacity at 100 PSIG (6.9 BAR) *** Noise levels taken with hot and cold mufflers installed. |
Vortex Tube Standards and Certifications


EXAIR Vortex Tubes comply with OSHA's Safety Requirements, the EU General Product Safety Directive (2001/95/EC) and meet the noise limitation requirements of the EU Machinery Directive (2006/42/EC). All sound level measurements are taken at 3 feet away.

Look for this symbol to designate conflict mineral free products throughout our website. EXAIR supports Section 1502 of the Dodd-Frank Wall Street Reform and Consumer Protection Act and we are committed to compliance with the conflict minerals rule in order to curb the illicit trade of tin, tantalum, tungsten and gold in the DRC region. EXAIR is using the CMRT 3.02 template to document our supply chain and commitment to conflict free products.
3400 Series Vortex Tube Specifications |
||||||
3400 series Vortex Tubes provide lowest cold air temperatures, but at low cold airflow (when less than a 50% cold fraction is used). Specify 3400 series Vortex Tubes only where temperatures below 0° (-18°C) are desired. | ||||||
Model # | SCFM* | SLPM* | Btu/hr.** | Watts** | Size | dBA*** |
3402 | 2 | 57 | -------- | -------- | Small | 67 |
3404 | 4 | 113 | -------- | -------- | Small | 69 |
3408 | 8 | 227 | -------- | -------- | Small | 75 |
3410 | 10 | 283 | -------- | -------- | Medium | 78 |
3415 | 15 | 425 | -------- | -------- | Medium | 80 |
3425 | 25 | 708 | -------- | -------- | Medium | 82 |
3430 | 30 | 850 | -------- | -------- | Medium | 84 |
3440 | 40 | 1,133 | -------- | -------- | Medium | 87 |
3450 | 50 | 1,416 | -------- | -------- | Large | 93 |
3475 | 75 | 2,124 | -------- | -------- | Large | 96 |
3498 | 100 | 2,832 | -------- | -------- | Large | 96 |