EN | FR
EN | FR

NEMA 4X St. St. HT Cabinet Cooler® Systems w Therm

High Temperature Cabinet Coolers for ambient temperatures of 125°F to 200°F (52°C to 93°C) are available in many cooling capacities for large and small control panels. Thermostat controlled cooler systems are the best option when experiencing fluctuating heat loads caused by environment or seasonal changes. The standard thermostat control systems include an adjustable thermostat factory set at 95°F (35°C). NEMA 4X (IP66) Cabinet Cooler® Systems (dust-tight, oil-tight, splash resistant, corrosion resistant, indoor/outdoor service) incorporate a low pressure relief valve for both the vortex tube and cabinet air exhaust. This valve closes and seals when the cooler is not operating to maintain the integrity of a NEMA 4X enclosure. They are a low cost, reliable way to cool and purge electronic control panels. All Cabinet Coolers are UL Listed and CE compliant. EXAIR Cabinet Coolers incorporate a vortex tube to produce cold air from compressed air - with no moving parts. The compact Cabinet Cooler can be installed in minutes through a standard electrical knockout.

Applications

  • Programmable controllers
  • Line control cabinets
  • Motor control centers
  • Relay panels
  • NC/CNC systems
  • Modular control centers
  • CCTV cameras
  • Computer cabinets
  • Cool laser housings
  • Electronic scales


NEMA 4X Cabinet Cooler Advantages

  • Low cost
  • Corrosion resistant in harsh environments
  • Compact
  • Cooling capacities up to 5,600 Btu/hr. (1,641 Watts)
  • Quiet
  • Install in minutes
  • Maintain NEMA 4X integrity (IP66)
  • Stabilize enclosure temperature and humidity
  • No CFC's
  • No moving parts - maintenance free
  • Mount in standard electrical knockout
  • Stop nuisance tripping
  • Stop heat damage
  • Eliminate fans and filters
  • Eliminate lost production
  • Stop circuit drift
  • Stop dirt contamination
  • Provide washdown protection


NEMA 4X (IP66) High Temperature Cabinet Cooler Systems - Type 303 Stainless Steel, Thermostat Control

Model Btu/hr. (Watts)
HT4815SS 1,000 (293)
HT4825SS 1,700 (498)
HT4830SS 2,000 (586)
HT4840SS 2,800 (821)
HT4850SS 3,400 (997)
HT4860SS 4,000 (1,171)
HT4870SS 4,800 (1,406)
HT4880SS 5,600 (1,641)

NEMA 4X (IP66) High Temperature Cabinet Cooler Systems - Type 316 Stainless Steel, Thermostat Control

Model Btu/hr. (Watts)
HT4815SS-316 1,000 (293)
HT4825SS-316 1,700 (498)
HT4830SS-316 2,000 (586)
HT4840SS-316 2,800 (821)
HT4850SS-316 3,400 (997)
HT4860SS-316 4,000 (1,171)
HT4870SS-316 4,800 (1,406)
HT4880SS-316 5,600 (1,641)

NEMA 4X (IP66) High Temperature Cabinet Cooler Systems - Type 303 Stainless Steel 240V, Thermostat Control Systems

Model Btu/hr. (Watts)
HT4815SS-240 1,000 (293)
HT4825SS-240 1,700 (498)
HT4830SS-240 2,000 (586)
HT4840SS-240 2,800 (821)
HT4850SS-240 3,400 (997)
HT4860SS-240 4,000 (1,171)
HT4870SS-240 4,800 (1,406)
HT4880SS-240 5,600 (1,641)

NEMA 4X (IP66) High Temperature Cabinet Cooler Systems - Type 316 Stainless Steel 240V, Thermostat Control Systems

Model Btu/hr. (Watts)
HT4815SS-316-240 1,000 (293)
HT4825SS-316-240 1,700 (498)
HT4830SS-316-240 2,000 (586)
HT4840SS-316-240 2,800 (821)
HT4850SS-316-240 3,400 (997)
HT4860SS-316-240 4,000 (1,171)
HT4870SS-316-240 4,800 (1,406)
HT4880SS-316-240 5,600 (1,641)

NEMA 4X (IP66) High Temperature Cabinet Cooler Systems - Type 303 Stainless Steel 24VDC, Thermostat Control Systems

Model Btu/hr. (Watts)
HT4815SS-24VDC 1,000 (293)
HT4825SS-24VDC 1,700 (498)
HT4830SS-24VDC 2,000 (586)
HT4840SS-24VDC 2,800 (821)
HT4850SS-24VDC 3,400 (997)
HT4860SS-24VDC 4,000 (1,171)
HT4870SS-24VDC 4,800 (1,406)
HT4880SS-24VDC 5,600 (1,641)

NEMA 4X (IP66) High Temperature Cabinet Cooler Systems - Type 316 Stainless Steel 24VDC, Thermostat Control Systems

Model Btu/hr. (Watts)
HT4815SS-316-24VDC 1,000 (293)
HT4825SS-316-24VDC 1,700 (498)
HT4830SS-316-24VDC 2,000 (586)
HT4840SS-316-24VDC 2,800 (821)
HT4850SS-316-24VDC 3,400 (997)
HT4860SS-316-24VDC 4,000 (1,171)
HT4870SS-316-24VDC 4,800 (1,406)
HT4880SS-316-24VDC 5,600 (1,641)


Side Mount Kits

Side Mount Kits for Cabinet Coolers

EXAIR's Side Mount Kits make mounting on the side of an electrical enclosure possible when there is limited space on the top or side. (NEMA 4 and 4X Cabinet Cooler Systems must be mounted vertically.) Side Mount Kits maintain the NEMA rating of large and small NEMA Type 12, 4, and 4X enclosures. they mount in a standard electrical knockout (1-1/2 NPS). Side Mount Kits for NEMA 12 Cabinet Cooler Systems have an aluminum construction. Those for NEMA 4 and 4X Cabinet Cooler Systems are Type 303 or Type 316 stainless steel.



NEMA 4X (IP66) High Temperature Type 303 Stainless Steel with Thermostat Control - Performance

Model Capacity Sound Level dBA
Btu/hr. Watts
HT4815SS, HT4815SS-240, HT4815SS-24VDC 1,000 293 73
HT4825SS, HT4825SS-240, HT4825SS-24VDC 1,700 498 80
HT4830SS, HT4830SS-240, HT4830SS-24VDC 2,000 586 80
HT4840SS, HT4840SS-240, HT4840SS-24VDC 2,800 821 82
HT4850SS, HT4850SS-240, HT4850SS-24VDC 3,400 997 84
HT4860SS, HT4860SS-240, HT4860SS-24VDC 4,000 1,171 84
HT4870SS, HT4870SS-240, HT4870SS-24VDC 4,800 1,406 84
HT4880SS, HT4880SS-240, HT4880SS-24VDC 5,600 1,641 85

NEMA 4X (IP66) High Temperature Type 316 Stainless Steel with Thermostat Control - Performance

Model Capacity Sound Level dBA
Btu/hr. Watts
HT4815SS-316, HT4815SS-316-240, HT4815SS-316-24VDC 1,000 293 73
HT4825SS-316, HT4825SS-316-240, HT4825SS-316-24VDC 1,700 498 80
HT4830SS-316, HT4830SS-316-240, HT4830SS-316-24VDC 2,000 586 80
HT4840SS-316, HT4840SS-316-240, HT4840SS-316-24VDC 2,800 821 82
HT4850SS-316, HT4850SS-316-240, HT4850SS-316-24VDC 3,400 997 84
HT4860SS-316, HT4860SS-316-240, HT4860SS-316-24VDC 4,000 1,171 84
HT4870SS-316, HT4870SS-316-240, HT4870SS-316-24VDC 4,800 1,406 84
HT4880SS-316, HT4880SS-316-240, HT4880SS-316-24VDC 5,600 1,641 85


Dimensions - NEMA 4X Cabinet Cooler

Models HT4815SS, HT4815SS-316, HT4825SS, HT4825SS-316, HT4830SS, HT4830SS-316, HT4840SS, HT4840SS-316
NEMA 4X Cabinet Cooler Dimensions


How Cabinet Coolers Work

How the Cabinet Cooler Works

Compressed air enters the vortex tube powered Cabinet Cooler and is converted into two streams, one hot and one cold. Hot air from the vortex tube is muffled and exhausted through the vortex tube exhaust. The cold air is discharged into the control cabinet through the cold air distribution kit. The displaced hot air in the cabinet rises and exhausts to atmosphere through the cabinet air exhaust at a slight positive pressure. Thus, the control cabinet is both cooled and purged with cool, clean air. Outside air is never allowed to enter the control panel.

Cabinet Cooler Standards and Certifications

OSHA Safe!

EXAIR's Cabinet Cooler Systems comply with OSHA's Safety Requirements, the EU General Product Safety Directive (2001/95/EC) and meet the noise limitation requirements of the EU Machinery Directive (2006/42/EC). In addition, Cabinet Cooler Systems are Listed to applicable UL Standards and requirements by Underwriters' Laboratories. All sound level measurements are taken at 3 feet away.

Conflict Mineral Free

Look for this symbol to designate conflict mineral free products throughout our website. EXAIR supports Section 1502 of the Dodd-Frank Wall Street Reform and Consumer Protection Act and we are committed to compliance with the conflict minerals rule in order to curb the illicit trade of tin, tantalum, tungsten and gold in the DRC region. EXAIR is using the CMRT 3.02 template to document our supply chain and commitment to conflict free products.

Talk to one of our Experts

Reach out to our team of Spraying, Pumping, Filtering, Valve, and Systems Specialists today. We know we can help you with any municipal or industrial application challenges.