Product | BTU/Hr | Solenoid Valve (Standard) Or ETC (Upgrade | Voltage | Material | Type | High Temp Or NHP | Vortex Capacity | Air Inlet | Filter |
![]() |
275 | Solenoid Valve | 120 V | Aluminum | NEMA 4 Thermostat Control Cabinet Cooler | Non Hazardous Purge | 4 SCFM (113 SLPM) | 1/8 FNPT | Not Included |
![]() |
275 | Solenoid Valve | 240V | Aluminum | NEMA 4 Thermostat Control Cabinet Cooler | Non Hazardous Purge | 4 SCFM (113 SLPM) | 1/8 FNPT | Not Included |
![]() |
550 | Solenoid Valve | 120V | Aluminum | NEMA 4 Thermostat Control Cabinet Cooler | Non Hazardous Purge | 8 SCFM (227 SLPM) | 1/8 FNPT | Not Included |
![]() |
550 | Solenoid Valve | 240V | Aluminum | NEMA 4 Thermostat Control Cabinet Cooler | Non Hazardous Purge | 8 SCFM (227 SLPM) | 1/8 FNPT | Not Included |
![]() |
1,000 | Solenoid Valve | 120V | Aluminum | NEMA 4 Thermostat Control Cabinet Cooler | Non Hazardous Purge | 15 SCFM (425 SLPM) | 1/4 FNPT | Not Included |
![]() |
1,000 | Solenoid Valve | 240V | Aluminum | NEMA 4 Thermostat Control Cabinet Cooler | Non Hazardous Purge | 15 SCFM (425 SLPM) | 1/4 FNPT | Not Included |
![]() |
1,700 | Solenoid Valve | 120V | Aluminum | NEMA 4 Thermostat Control Cabinet Cooler | Non Hazardous Purge | 25 SCFM (708 SLPM) | 1/4 FNPT | Not Included |
![]() |
1,700 | Solenoid Valve | 240V | Aluminum | NEMA 4 Thermostat Control Cabinet Cooler | Non Hazardous Purge | 25 SCFM (708 SLPM) | 1/4 FNPT | Not Included |
![]() |
2,000 | Solenoid Valve | 120V | Aluminum | NEMA 4 Thermostat Control Cabinet Cooler | Non Hazardous Purge | 30 SCFM (850 SLPM) | 1/4 FNPT | Not Included |
![]() |
2,000 | Solenoid Valve | 240V | Aluminum | NEMA 4 Thermostat Control Cabinet Cooler | Non Hazardous Purge | 30 SCFM (850 SLPM) | 1/4 FNPT | Not Included |
![]() |
2,800 | Solenoid Valve | 120V | Aluminum | NEMA 4 Thermostat Control Cabinet Cooler | Non Hazardous Purge | 40 SCFM (1,133 SLPM) | 1/4 FNPT | Not Included |
![]() |
2,800 | Solenoid Valve | 240V | Aluminum | NEMA 4 Thermostat Control Cabinet Cooler | Non Hazardous Purge | 40 SCFM (1,133 SLPM) | 1/4 FNPT | Not Included |
![]() |
3,400 | Solenoid Valve | 120V | Aluminum | NEMA 4 Thermostat Control Cabinet Cooler | Non Hazardous Purge | 50 SCFM (1,416 SLPM) | 1/4 FNPT | Not Included |
![]() |
3,400 | Solenoid Valve | 240V | Aluminum | NEMA 4 Thermostat Control Cabinet Cooler | Non Hazardous Purge | 50 SCFM (1,416 SLPM) | 1/4 FNPT | Not Included |
![]() |
4,000 | Solenoid Valve | 120V | Aluminum | NEMA 4 Thermostat Control Cabinet Cooler | Non Hazardous Purge | 60 SCFM (1,699 SLPM) | 1/4 FNPT | Not Included |
![]() |
4,000 | Solenoid Valve | 240V | Aluminum | NEMA 4 Thermostat Control Cabinet Cooler | Non Hazardous Purge | 60 SCFM (1,699 SLPM) | 1/4 FNPT | Not Included |
![]() |
4,800 | Solenoid Valve | 120V | Aluminum | NEMA 4 Thermostat Control Cabinet Cooler | Non Hazardous Purge | 70 SCFM (1,982 SLPM) | 1/4 FNPT | Not Included |
![]() |
4,800 | Solenoid Valve | 240V | Aluminum | NEMA 4 Thermostat Control Cabinet Cooler | Non Hazardous Purge | 70 SCFM (1,982 SLPM) | 1/4 FNPT | Not Included |
![]() |
5,600 | Solenoid Valve | 120V | Aluminum | NEMA 4 Thermostat Control Cabinet Cooler | Non Hazardous Purge | 80 SCFM (2,265 SLPM) | 1/4 FNPT | Not Included |
![]() |
5,600 | Solenoid Valve | 240V | Aluminum | NEMA 4 Continuous Operation Cabinet Cooler | Non Hazardous Purge | 80 SCFM (2,265 SLPM) | 1/4 FNPT | Not Included |
Applications:
- Programmable controllers
- Line control cabinets
- Motor control centers
- Relay panels
- NC/CNC systems
- Modular control centers
- CCTV cameras
- Computer cabinets
- Cool laser housings
- Electronic scales
NEMA 4 Cabinet Cooler Advantages:
- Low cost
- Compact
- Cooling capacities up to 5,600 Btu/hr. (1,641 Watts)
- Quiet
- Install in minutes
- Maintain NEMA 4 integrity (IP66)
- Stabilize enclosure temperature and humidity
- No CFC's
- No moving parts - maintenance free
- Mount in standard electrical knockout
- Stop nuisance tripping
- Stop heat damage
- Eliminate fans and filters
- Eliminate lost production
- Stop circuit drift
- Stop dirt contamination
- Provide washdown protection
Models:
NEMA 4 (IP66) Non Hazardous Purge Cabinet Cooler Systems, Thermostat Control (120V) |
|
Model | Btu/hr. (Watts) |
NHP4804 | 275 (80) |
NHP4808 | 550 (162) |
NHP4815 | 1,000 (293) |
NHP4825 | 1,700 (498) |
NHP4830 | 2,000 (586) |
NHP4840 | 2,800 (821) |
NHP4850 | 3,400 (997) |
NHP4860 | 4,000 (1,171) |
NHP4870 | 4,800 (1,406) |
NHP4880 | 5,600 (1,641) |
NEMA 4 (IP66) Non Hazardous Purge Cabinet Cooler Systems, Thermostat Control (240V) |
|
Model | Btu/hr. (Watts) |
NHP4804-240 | 275 (80) |
NHP4808-240 | 550 (162) |
NHP4815-240 | 1,000 (293) |
NHP4825-240 | 1,700 (498) |
NHP4830-240 | 2,000 (586) |
NHP4840-240 | 2,800 (821) |
NHP4850-240 | 3,400 (997) |
NHP4860-240 | 4,000 (1,171) |
NHP4870-240 | 4,800 (1,406) |
NHP4880-240 | 5,600 (1,641) |
Performance:
NEMA 4 (IP66) Non Hazardous Purge Cabinet Cooler with Thermostat - Performance |
||||
Model | Capacity | Sound Level dBA | ||
Btu/hr. | Watts | |||
NHP4804, NHP4804-240 | 275 | 80 | 59* | |
NHP4808, NHP4808-240 | 550 | 162 | 67* | |
NHP4815, NHP4815-240 | 1,000 | 293 | 73 | |
NHP4825, NHP4825-240 | 1,700 | 498 | 80 | |
NHP4830, NHP4830-240 | 2,000 | 586 | 80 | |
NHP4840, NHP4840-240 | 2,800 | 821 | 82 | |
NHP4850, NHP4850-240 | 3,400 | 997 | 84 | |
NHP4860, NHP4860-240 | 4,000 | 1,171 | 84 | |
NHP4870, NHP4870-240 | 4,800 | 1,406 | 84 | |
NHP4880, NHP4880-240 | 5,600 | 1,641 | 85 | |
*With optional cold muffler installed. Cooling Capacity at 100 PSIG (6.9 BAR) Supply Pressure. |
Dimensions:
NEMA 4 Non Hazardous Purge Cabinet Coolers with Thermostat |
|
![]() |
![]() |
ModelsNHP4804, NHP4804-240 |
ModelsNHP4815, NHP4825, NHP4830, NHP4840 |
How It Works:
Compressed air enters the vortex tube powered Cabinet Cooler and is converted into two streams, one hot and one cold. Hot air from the vortex tube is muffled and exhausted through the vortex tube exhaust. The cold air is discharged into the control cabinet through the cold air distribution kit. The displaced hot air in the cabinet rises and exhausts to atmosphere through the cabinet air exhaust at a slight positive pressure. Thus, the control cabinet is both cooled and purged with cool, clean air. Outside air is never allowed to enter the control panel.
Cabinet Cooler Standards and Certifications



EXAIR's Cabinet Cooler Systems comply with OSHA's Safety Requirements, the EU General Product Safety Directive (2001/95/EC) and meet the noise limitation requirements of the EU Machinery Directive (2006/42/EC). In addition, Cabinet Cooler Systems are Listed to applicable UL Standards and requirements by Underwriters' Laboratories. All sound level measurements are taken at 3 feet away.

Look for this symbol to designate conflict mineral free products throughout our website. EXAIR supports Section 1502 of the Dodd-Frank Wall Street Reform and Consumer Protection Act and we are committed to compliance with the conflict minerals rule in order to curb the illicit trade of tin, tantalum, tungsten and gold in the DRC region. EXAIR is using the CMRT 3.02 template to document our supply chain and commitment to conflict free products.